Does severe surface reflection, poor screen visibility under strong light, screen corrosion and fogging caused by alcohol wiping, glass atomization, accelerated screen aging, insufficient brightness and severe color deviation bring great inconvenience to your daily work? How should you choose the right product to solve these problems effectively?
Features of lcd screen touch 15.6 inch1.Chip: Equipped with medical-grade high anti-interference touch IC. Optimized touch algorithms raise the sensing threshold for insulating materials including nitrile and latex gloves, enabling direct touch control with surgical gloves.
2.Lamination Process: Adopts full OCA lamination technology to reduce moisture and fog accumulation inside the screen gap, eliminating internal light refraction and capacitive signal disorder in humid environments.
3.
Adopting G+G dual tempered glass structure to enhance panel tightness and block the penetration of normal saline, body fluids and disinfectants into the edges of the touch layer.
4.
Featured with dual-coating of AG anti-glare and AR anti-reflection on the surface, combined with hydrophobic, oleophobic and anti-electrolyte coating, it effectively reduces the occurrence of touch drift.
5.Equipped with an overall ESD anti-static protection design, and a shielding layer is added to the touch panel. It isolates micro-current interference generated by body fluids and disinfectants, stabilizes capacitive sampling signals, and eliminates random touch points and touch drift issues.
6.The medical-grade chip is embedded with enhanced high-frequency filtering and pulse suppression algorithms, delivering optimized shielding for high-frequency bands to suppress electromagnetic interference. Meanwhile, multi-layer shielding is added to the touch layer, and the touch FPC flexible cable adopts fully shielded wrapping and twisted pair wiring design for further EMI isolation.
7.An EMI filter, magnetic ring, varistor and voltage stabilization module are added at the power input terminal to filter out high-frequency clutter and voltage fluctuations, preventing touch abnormalities caused by power interference.
8.Multiple stages of hardware filter circuits are added for touch signals to filter high-frequency clutter sampling signals, eliminating coordinate drift and accidental false touches caused by interference.
9.Adopts an independent touch power supply design to isolate interference from high-power circuits of the whole device and ensure stable sampling of touch signals.
Specifications
| Items |
Specifications |
| Product Number |
EG-15.6-A-1609V1-QTCTP-A |
| Touch Panel P/N |
EG-15.6-A-1609V1 |
| Display P/N |
G156HAN02.302 |
| Screen Diagonal |
15.6/16:9 |
| Cover Outline Dimension |
380.56*229.99mm |
| Touch Panel View Area |
344.56*193.99mm |
| Touch Panel Active Area |
345.56*194.99mm |
| Touch Panel Thickness |
2.9mm |
| Display Outline Dimension |
363.8*215.9mm |
| Display Active Area |
344.16*193.59mm |
| Display Thickness |
8.8mm |
| Impact resistance |
≥IK07 |
| Support Touch Points |
10 points Typ. |
| Controller Interface |
USB Typ. |
| Transmittance |
>85% |
| Pixels H×V |
1920 x 3(RGB) x 1080 |
| Support Color |
16.7M Colors |
Shipping and Return Police:
1.By sea, land, air and other transportation methods.
2.For quality issues: 7-day free return, 30-day replacement, and 3-year warranty.
Packaging: We provide two packaging options: high-quality hard cartons and eco-friendly renewable wooden cases.
Payment methods: T/T, L/C, PayPal and other options available.
FAQ1.What medical devices can this 15.6-inch touch module be applied to?It is applicable to patient monitors, medical carts, ultrasound & endoscopy equipment, operating room control panels, nurse station terminals, diagnostic imaging devices and more, fully meeting the demands of clinical diagnosis and monitoring scenarios.
2.Does it support operation with medical gloves, wet hands, and in disinfectant-contacted scenarios?Supports stable touch control with surgical gloves, nitrile gloves, wet hands, water film and disinfectant contact. No touch drift or false touches, perfectly suitable for high-frequency use in operating rooms and ICU.
3.Can the screen be wiped with alcohol and chlorine-containing disinfectants for long-term use?Medical-grade corrosion-resistant cover glass with antibacterial coating is adopted. It withstands repeated wiping with 75% alcohol, quaternary ammonium salts and chlorine-containing disinfectants, without whitening, fogging or coating peeling.
4.Does it comply with medical safety regulations and EMC requirements?Yes, Supports IEC 60601-1 medical safety and IEC 60601-1-2 EMC standards. Featuring low leakage current and strong anti-interference performance, it will not affect the normal operation of electrosurgical units, ventilators and other medical devices.
5.Can the screen be clearly viewed under strong light in the operating room? Is the reflection obvious?Comes standard with high brightness of 400–1000 cd/m², full-view IPS panel, and AG anti-glare & AR anti-reflection coating. It eliminates strong glare under surgical shadowless lamps, delivers no color deviation from multiple viewing angles and ensures eye-friendly viewing.
Recommend Products1.Optical Bonding Services | 15.6 Inch | Ever Glory2.Touch Panel Display 7 Inch | Capacitive Touch | Ever Glory3.capacitive touch screen display 15.6 inch 10 touch points panel4.finger touch capacitive 15 inch touch display industrial supplier5.12.1 Inch Optical Bonding 10 Touch Points IP65 Waterproof High Resolution Capacitive Pcap Touch Screen Display