Need a module that fits your machine, works with your host and can be qualified for repeat production?
Whether you are replacing a discontinued display or developing a new operator interface, start with a defined LCD and PCAP configuration. Review mechanical fit, display and touch connections, operating conditions and production requirements before committing to samples.
Share the dimensions, host interfaces and operating requirements that your replacement or new assembly must meet.
Start with these published configurations. Compare the complete mechanical and electrical specifications before selecting a sample.
| Model | Display | Brightness | Interfaces | Operating Temperature | Bonding / Assembly |
|---|---|---|---|---|---|
| EG-12.1-228-QTMZ-V1 Product details — French |
12.1 inch, 4:3 Resolution: request LCD datasheet |
1,000 cd/m² advertised* | Touch: USB, 10 points Display: request configuration details |
−20 to +70 °C | Perimeter adhesive attachment |
| EG-21.5-553-QTMZ-V1 Product details — French |
21.5 inch IPS, 16:9 1920 × 1080 |
250 cd/m² typical, LCD only | Display: dual-channel LVDS Touch: USB, 10 points |
0 to +50 °C | Confirm the quoted assembly configuration |
Compare overall dimensions, viewing area, thickness, mounting points and cable clearance. A matching screen diagonal does not establish a drop-in replacement.
Review the video connection separately from touch communication. Identify any LCD driver board, host software requirements and power accessories needed for evaluation.
Confirm the LCD, touch panel, bonding, controller, boards, cables and mounting parts in the quotation. A module is not automatically a complete monitor or programmable HMI.
Define the operating conditions and acceptance criteria before testing. General capabilities do not replace verification of your selected module and final installation.
Evaluate touch behaviour with the intended power supply, grounding, enclosure and cable routing. Include machine start-up and switching conditions, not only a quiet bench setup.
Specify glove material and thickness, liquid exposure and cleaning methods. Distinguish operation with wet fingers from preventing unintended input during water exposure or wiping.
Select the complete assembly against enclosure temperature, heat sources and duty cycle. Confirm applicable LCD, backlight, bonding and touch-component limits.
ESD protection up to ±8 kV contact discharge is subject to configuration and verified test conditions. Any front IP requirement must be assessed with the defined glass, seal and enclosure arrangement.
Ever Glory’s published project overview covers 10.1-, 15.6- and 18.5-inch touch display modules for CNC sheet metal equipment.
Relevant to your review: multiple screen formats, operator-interface integration and project-specific customization.
Read the CNC Module Project →This published reference concerns 11.6- and 13.3-inch touch panels for industrial HMI, rather than complete LCD modules.
Relevant to your review: cover-glass adaptation, FPC routing and integration with the equipment front panel.
Read the HMI Touch Panel Reference →Explore the published process and inspection information, then request the documents applicable to the proposed module.
Review bonding methods, material-selection factors and inspection considerations for touch and LCD integration.
View Bonding Processes →Review the available testing and inspection capabilities. Define which tests and acceptance criteria apply to your configuration.
View Inspection Resources →Request current documents and verify the holder, site, scope, validity and applicability to the supplied product.
View Compliance Information →Review cover-glass outline and printing, FPC routing, controller configuration, surface treatment and bonding around your fixed mechanical and electrical constraints. Identify changes to a standard configuration separately so their development cost, validation scope and schedule are clear.
Send your supplier questionnaire and document requirements during project review. Agree on the qualification package, available records and any additional testing before supplier approval.
| Procurement Concern | Documents and Arrangements to Agree |
|---|---|
| Supplier Identity & Scope | Company information, manufacturing scope and applicable current quality-system certificates. |
| Sample-to-Production Consistency | Approved reference sample, module specification, BOM and drawing revisions, inspection criteria and supplied accessories. |
| Firmware & Parameter Changes | Record the approved controller, hardware, firmware and parameter-file versions where applicable. Define change approval and regression-test requirements for the program. |
| Batch Quality & Traceability | Applicable inspection checklist, sampling scope, available batch records, identification method and record-retention requirements. |
| LCD Availability & Lifecycle | LCD sourcing, proposed alternatives, requalification needs, PCN and last-time-buy arrangements. Supply commitments require written project agreement. |
| Quality Incidents & Warranty | Claim procedure, evidence needed, return authorization and failure-analysis scope. If an 8D report is required, agree on its applicability, deliverables and timing. |
Engineering samples are quoted separately. Batch production starts at 100 units; this minimum does not apply to sample orders. Pilot-run feasibility and quantities require separate agreement.
Ask the quotation to identify material availability, additional engineering, sample preparation and production timing. Module lead times depend on the LCD, bonding, customization and order quantity; shipping is separate.
Warranty: 3 years, with coverage and the claim process confirmed for the supplied assembly. The 3-day sample policy for standard non-bonded touch panels does not automatically apply to LCD-integrated modules.
A useful proposal should give your engineering and purchasing teams a clear basis for the next decision.
Recommended module or development scope, display and touch connections, included accessories and unresolved compatibility questions.
Available specifications and outline drawings, plus the proposed evaluation scope and any additional information needed from your team.
Sample quotation, separately identified development or tooling charges, estimated preparation time and assumptions for production planning.
Send the original reference, mechanical drawing and host details. Compatibility requires comparison of the LCD, mounting, interfaces, touch configuration and software behaviour; screen size alone is insufficient.
No. References illustrate application experience. Test results must match the relevant configuration and conditions, and your finished equipment requires its own validation.
Include this requirement in the supplier review. Define the controlled configuration, notification process, approval responsibilities and revalidation requirements in the project agreement.
Share the failure conditions and equipment configuration for review. Agree on proposed adjustments, revised samples, additional charges and timing before further development.
Request an NDA review and establish confidentiality arrangements before sending sensitive drawings or project documents.
Send your selected model or existing part number, host details, installation drawing and sample quantity.